EP is the relevant Evaluation Period stated elsewhere
in this Contract;
i is the sequential number of each Measurement Period
in the Evaluation Period;
MP is the relevant Measurement Period of [15 minutes]
each;
is the unshaded insolation (kWh/m²) in the plane of array
measured in accordance with paragraph 2.7 below during the relevant
Measurement Period.
2 MEASURED PRMP
2.1 Determination of Measured
PRMP
Measured PRMP shall be determined and calculated as follows:
whereby:
Measured PRMP is the Measured PR
(dimensionless) for the relevant Measurement Period;
MP is the relevant Measurement Period;
EbACis the energy actually metered (kWh) by
the HV meter at Delivery Point during the Measurement Period;
[Drafting note: If energy generated by the Facility is
used to provide auxiliary power (rather than drawing auxiliary
power from the grid), it would be appropriate to add the auxiliary
power to EAC. However, in such case there should be