The insured, Mississippi River Power Corporation (the
"Company") operated a power generation station on the
Mississippi River in Almonte, Ontario. The station was expanded
starting in 2008. The new station began operations in 2010 and
featured two new large diameter pipes, encased in concrete, called
"penstocks". The penstocks were designed to channel water
to the station's hydraulic turbines.
In April 2012, Penstock #2 failed and collapsed on itself,
severely restricting the flow of water to the turbines. The cause
of failure was found to have been defective welding.
As a precautionary measure, the Company decided to inspect
Penstock #1, which had not yet failed, as it was of identical
design and construction. The inspection revealed that the quality
of the welding in Penstock #1 was not acceptable in many locations
and that there was a risk that Penstock #1 could collapse in the
future.