A school board has been handed a $250,000 fine under the Ontario
Occupational Health and Safety Act after the death of
maintenance worker.
The maintenance worker had been assigned the task of replacing a
safety cage on a ceiling light in a high school gymnasium. He
was working alone. While he was rolling a portable aerial
device (a type of lifting device) down a ramp off a trailer, the
aerial device tipped over and struck the worker, fatally injuring
him.
The angle of the ramp was about eight degrees, while the manual
for the aerial device stated that it should not be rolled down an
incline greater than five degrees.
The school board pleaded guilty to the OHSA charge of failing as
an employer to take every precaution reasonable in the
circumstances for the protection of a worker. In particular,
the school board failed to ensure that the angle of the ramp was
five degrees or less; that the aerial device was rolled down the
ramp with its mast on the upper or